GFCI Removal for Troubleshooting Procedure

1. Turn the GFCI module over to the side with the 2 plug-in prongs.
2. Remove the 4 screws below the prongs using a Philips head screwdriver.
3. Remove the plastic cover.
4. Remove the 4 Philips screws that hold the power cord inside the module.
5. Attach the White and Black wires to a standard 2 pronged plug.